Description
Scope of supply:VCC: 3.3 V ~ 3.6 VDC: current 100 ma
Technical parameters
Measuring range |
0.05 ~ 35 m |
Measure precision (standard deviation) |
1.0 mm |
The output |
UART serial digital output |
From the unit |
m |
Laser type |
620 ~ 690 nm |
Laser level |
Ⅱ level, |
In the spot diameter from m |
6 mm @ 10 m, 30 mm @ 50 m |
Measure the frequency |
1-10 hz |
Protection grade |
IP40 |
Working temperature |
- 10 ~ + 50 ℃ up to 90℃ |
Storage temperature |
- 20 ~ + 80 ℃ |
The weight of the |
About 60 g |
Size (length x width x height) |
21 * 11 * 26 mm |
Execution standard |
GB/T 14267-2009
|
For different goals and measurement environment, due to the large environmental light intensity, environmental temperature is too high or too low, target reflection too weak or too strong, or target rough surface, can cause measuring process shorten or produce large error to measurement results.