Description
Features
TOUCH SCREEN
Temperature Display
Temperature Control
Manual, automatic defrost by electric heater
Evap. Fan Control/ Value Storing
Self Testing /Parameter Locking
Technical Data
Range of temperature display:-45~66℃ (-45~150℉)
Range of set temperature:-45~45℃ (-45~120℉)
Accuracy:±1℃ (±2℉)
Compressor: N.O. 30A/250VAC
Defrost: N.O. 30A/250VAC
Evap.Fan: N.O. 30A/250VAC
Dimension:171(Length)×38(Width)×18(Depth)mm
Mounting hole dimension:164(Length)×30.5(Width)mm
Parameters
Parameter
|
Function
|
Set range
|
Default
|
E1
|
Lower setpoint limit
|
-45℃/-45℉~Set temp.
|
-35℃/-31℉
|
E2
|
Higher setpoint limit
|
Set temp.~45℃/120℉
|
20℃/68℉
|
E3
|
Temp.Hysteresis
|
1~10℃/1~18℉
|
4℃/7℉
|
E4
|
Comp.start delay time
|
0~10Min
|
2Min
|
E5
|
Offset on room temp.
|
-20~20℃/-36~36℉
|
0
|
E6
|
Offset on evap.temp.
|
-20~20℃/-36~36℉
|
0
|
F1
|
Max.defrost duration
|
1~60Min
|
20Min
|
F2
|
Defrost interval time
|
0~24Hr
|
6Hr
|
F3
|
Defrost termination temp.
|
0~20℃/32~68℉
|
8℃/46℉
|
F4
|
Display during defrost
|
0=Normal display
1=Last value before defrost |
0
|
F5
|
Fan operating function
|
0=Parallel with comp.
1=Continuous running except defrost
|
0
|
C1
|
Temperature unit
|
C=℃ F=℉
|
C
|