SF-205 SHANGFANG Adjustable thermostat temperature control:-45°C~150°C defog

(No reviews yet) Write a Review
Weight:
0.55 KGS
  • SF-205 SHANGFANG Adjustable thermostat temperature control:-45°C~150°C defog
  • SF-205 SHANGFANG Adjustable thermostat temperature control:-45°C~150°C defog
  • SF-205 SHANGFANG Adjustable thermostat temperature control:-45°C~150°C defog
  • SF-205 SHANGFANG Adjustable thermostat temperature control:-45°C~150°C defog
  • SF-205 SHANGFANG Adjustable thermostat temperature control:-45°C~150°C defog
Eur€ 44.38

Description

Features 

It is an intelligent controller

and applicable to the compressor of one HP.

Temperature Display / Temperature Control

Automatic defrost by electric heater or hot gasLight Control

Electric heater defog

High,Low temperature alarm

Self Testing /Parameter Locking

Technical Data 
Range of temperature display:
45150       

Range of set temperature:4550         

Accuracy:±1

Temperature sensor: NTC, two sensors,2m(L)
Compressor:  N.O.  30A/250VAC  (applicable to one HP  Compressor, if more it needs to connect an  AC contactor)

Defrost:      N.O. 10A/250VAC              

Evap. Fan:    N.O.  5A/250VAC

Light:        N.O.  5A/250VAC               

Defog:       N.O. 10A/250VAC

Dimensions:142(Length)×40(Width)×40(Depth)mm

Mounting hole dimensions:138(Length)×32.5(Width)mm

Parameters 

 

Paramete

Function

Set range

Default

E1

Lower setpoint limit

45Set temp.

30

E2

Higher setpoint limit

Set temp.50

30

E3

Temp.hysteresis

110

4

E4

Comp.start delay time

010Min

2Min

E5

Offset on room temp.

1010

0

E6

Offset on evap.temp.

1010

0

F0

Defrost function

0=Electric heater

1=Hot gas

0

F1

Max.Defrost duration

160Min

20Min

F2

Defrost interval time

024Hr

6Hr

F3

Defrost termination temp.

0500

8

F4

Display during defrost

0=Normal display
1=Last value before defrost

0

F5

Dripping time after defrost

010Min

2Min

H1

Fan start delay time

010Min

1Min

H2

Fan operating function

0=Parallel with comp

1=Continuous running except defrosting

1

H3

Fan control during defrosting.

0=always OFF 1=always ON

0

C2

High temperature alarm

C3130

40

C3

Low temperature alarm

45C2

40

C4

Alarm delay time

1901Min

60Min