Description
Product Description
Plug-n-play Intelligent Temperature and Humidity Controller , Electronic Thermostat
For room humidification dehumidification, greenhouses, fermentation tank insulation, thermal control, piano moisture, temperature and humidity control and other related applications.
Controller with heating and cooling, humidification and dehumidification function, you can set up their own combinations. Socket on the left for the humidity control, the right for temperature control
As long as the humidifier or dehumidifier, heater or refrigeration equipment plugged into the controller above can be used.
WST-DS1 intelligent temperature and humidity controller Introduction
The instrument function of each button clear through the relay off to achieve automatic control, the controller will change according to temperature and humidity conditions automatically shut down or start control equipment.
1.This machine parameters:
Temperature measuring range: 0-99.9 oC Humidity measuring range :20-99 .9% RH
Sensor: AM2301
Temperature display resolution: 0.1 oC Temperature measurement error:+-0.5 oC
Temperature control resolution: 0.1 oC
Humidity Display Resolution: 0.1% RH Humidity measurement error:+-3% RH
Humidity Control Resolution: 0.1% RH
Output Type: Relay (contact capacity 250V, 10A)
Case size: 87mm x 135mm x 45mm
Working voltage: AC85 ~ 242V 50Hz/60Hz
2 Parameter Settings Operation:
1) powered display observation value, if not change the setting, the setting automatically credited to the original data is automatically controlled operation.
2) change the controlled parameter settings: in an energized state, long press SET key to enter the menu mode, according to the corresponding parameters to adjust, press "up" or "down" key to change the setting, "up" is used to increase the parameter setting, "down" is used to reduce the parameter setting, and press the "SET" will adjust the good data memory, and then returned to the control of temperature and humidity controller running state.
3) Do not use the actual lower limit is higher than the upper limit.
4) temperature and humidity sensor short circuit fault an error message: "Err".
3 Installation: The machine is compact design, the instrument must be kept at ambient temperature -5oC ~ +65 oC between, the instrument shall be placed in the absence of moisture and pressure of the occasion, and to vent for easy heat dissipation.
4 Wiring: the need to control the device inserted in the socket on the panel, instrument power supply must be in accordance with the specifications of the instrument superscript some power supply.
symbol |
project |
content |
factory setting |
unit |
rH1 |
Humidity upper limit |
0-99.9 |
80 |
%RH |
rL1 |
Humidity lower limit |
0-99.9 |
70 |
%RH |
rH2 |
Temp upper limit |
0-99.9 |
22 |
oC |
rL2 |
Temp lower limit |
0-99.9 |
20 |
oC |
HH |
Temp alarm upper limit |
1-99.9 |
95 |
oC |
LL |
Temp alarm lower limit |
0-99.0 |
10 |
oC |
HC1 |
Humidification / dehumidification mode switching |
00-70 |
00 |
00: Humidification 01: Dehumidification |
HC2 |
Heating / cooling mode switch |
00-70 |
00 |
00: Heating 01: Cooling |
Application Example Set reference: (heating equipment, humidification equipment, users are required to buy their own, this is just the controller itself does not heat, nor humidification)
1. Humidification mode:
Limit set to 80% humidity, the humidity range 70% humidification mode, the internal data set: rH1 = 80.0, rL1 = 70.0, HC1 = 00 actual work namely: humidity less than 70% on the start humidifier, reaches 80% stop humidifier.
2. Dehumidification mode:
Let humidity limit 90%, minimum 80% humidity, dehumidification mode, the internal data set: rH1 = 90.0, rL1 = 80.0, HC1 = 01 actual work namely: humidity of over 90% on the start dehumidifiers, down 80% dehumidifier stops.
3. Heating mode:
Set temperature limit of 25 degrees, the temperature limit of 23 degrees, the heating mode, the internal data set: rH2 = 25.0, rL2 = 23.0, HC2 = 00 actual work namely: the temperature is below 23 degrees to start heating, reaches 25 degrees stop heating.
4. Cooling mode:
Set temperature limit of 30 degrees dew recognize twin embarrassed? 28 degrees, the cooling mode, the internal data is set to: rH2 = 30.0, rL2 = 28.0, HC2 = 01 actual work namely: temperature above 30 degrees on the start cooling, lowering to 28 degrees to stop cooling.
GUARANTEE & WARRANTY:
- 100% fully checked and QC passed from factory.
- Original packaging and accessories produced by the manufacturer.
- One Year Warranty from the date of shipment
Payment:
- We accept payment by Credit Card, Bank Transfer and other Payment that Aliexpress support.
- Payment must be received within 19 days of auction closing
- Please list your special requests (color, packages, value of declaration, etc.) when you make payment, or send message to us.