Description
Biometric fingerprint control switch relay output car ignition elevator device control door access control
Parameters:
CPU: STM32F205RC (ST advanced digital processor)
Sensor: Precision optical fingerprint head (TFS-D400)
Memory: On-chip memory (expandable memory)
Fingerprint capacity: 100 (extension 1000)
False Accept Rate: <0.001% (safety class 5)
FRR: <0.1% (safety class 5)
Electric current: 50ma
Input time: <0.1 seconds
Comparison time: <0.1 seconds
Comparison method: 1: N
Security Level: 1-10 (can be customized)
Board Size: 45 * 65 * 18mm
Fingerprint head size: 20 * 24 * 52mm
Power supply: DC 7-30V (recommendation 12V)
Button: 4-H (start, add, delete, clear)
Upgrade Interface: USB
Output Format: Relay normally open or normally closed
Output Time: 0.1-550 seconds
Output Regulation: Adjustable (USB interface, PC software adjustment)
Operating temperature: -20 ° C to 60 ° C
Relative humidity: 40% RH-85% RH (non-condensing)
Output mode:
A Model: TFS-T72A
working principle:
Power on, the module keep in working condition, that is power on state:
Press the fingerprint once, success, output closed signal (uncharged); ------ open
Press the fingerprint again, success,output disconnect signal; ------ close
Press the fingerprint again, success, output closed signal ; ------ open
Press fingerprint again, success,output disconnect signal; ------ close
. . . . . . (Circulation output)
B Model: TFS-T72B
working principle:
Power on, the module keep in working condition, that is power on state:
Press fingerprint, verify successfully, output closed signal (uncharged), continuously output 0.1-990 seconds (time can be
set as desired), then automatically stop output (disconnect)
C model: model: TFS-T72C
Working principle:
After the power supply, the module is completed a cycle after the module into the sleep state (power saving state, mainly used in battery powered, power saving products), that is, the power saving mode:
First according to power on health, starting module, again according to the fingerprint, after successful verification, closed output signal (uncharged), continuous output 0.1-550 seconds (time can be set according to requirements), automatic stop output (disconnected) module into the dormant state.
Listing:
Module*1
Key board and line (3 keys)*1
Lights and wire*1
Start switch and wire *1
Power input lead *1
Output signal lead *1