Technical Data
Range of displayed: 0~99%RH
Regulating range:10~90%RH
Accuracy:±5%RH
Dehumidify relay: N.O. 10A/250VAC
Humidification relay: N.O. 8A/250VAC
Dimension:77(Length)×35(Width)×60(Depth)mm
Mounting hole dimension:71(Length)×29(Width)mm
Parameters
Parameter
|
Function
|
Set range
|
Default
|
E1
|
Lower setpoint limit
|
10%RH~Set temp.
|
40%RH
|
E2
|
Higher setpoint limit
|
Set temp.~90%RH
|
70%RH
|
E3
|
Humi. hysteresis
|
5~5%RH
|
20%RH
|
E4
|
Humidificationo hysteresis
|
5~5%RH
|
20%RH
|
E5
|
Transformation delay time
|
0~10Min
|
5Min
|
E6
|
Offset on humidity
|
-30~30%RH
|
0%RH
|
C1
|
Low humidity alarm
|
1%RH~C2
|
40%RH
|
C2
|
High humidity alarm
|
C1~99%RH
|
70%RH
|
C3
|
Alarm delay time
|
0~90~0Min
|
90Min
|