Description
Features
Temperature control
Light control
manual/automatic defrost by turning off
Time/temp. seting to end defrost
Re-start delay
Celsius/Fahrenheit degrees
Relay output :1HP(compressor)
Technical Data
Range of temperature display:—45~45℃ (-40~120℉)
Range of set temperature:—45~45℃ (-40~120℉)
Accuracy:±1℃ (±2℉)
Compressor: N.O. 20A/250VAC(one HP)
Light: N.O. 5A/250VAC
Dimension:77(Length)×35(Width)×60(Depth)mm
Mounting hole dimension:71(Length)×29(Width)mm
Parameters
Parameter
|
Function
|
Set range
|
Default
|
E1
|
Lower setpoint limit
|
-45℃/-40℉~Set temp.
|
-35℃/-31℉
|
E2
|
Higher setpoint limit
|
Set temp.~45℃/120℉
|
20℃/68℉
|
E3
|
Temp.Hysteresis
|
1~10℃/1~18℉
|
4℃/7℉
|
E4
|
Comp.start delay time
|
0~10Min
|
2Min
|
E5
|
Offset on room temp.
|
-5~5℃/℉
|
0
|
E6
|
Offset on evap.Temp.
|
-5~5℃/℉
|
0
|
F1
|
Max.Defrost duration
|
1~60Min
|
20Min
|
F2
|
Defrost interval time
|
0~24Hr
|
6Hr
|
F3
|
Defrost termination temp.
|
0~20℃/32~68℉
|
8℃/46℉
|
F4
|
Display during defrost
|
0=Normal display
1=Last value before defrost |
0
|
C1
|
Temperature unit
|
0=℃ 1=℉
|
0
|