Description
1. Waterproof & hermetic
2. Can control 1HP compressor directly
3. Defrost by turning off the compressor
4. Alram for highlow temperature overrun
5. Alarm delay
6. Parameter locking
7. Temperature range:-45 to 99oC
8. Accuracy: ±1oC
9. Sensor: NTC, 1pc
10.Power supply: 230VAC or 120VAC, 50 / 60Hz
11. Compressor: 30A / 250VAC
12. Dimension:142(L)×38(W)×35(D)mm
Paramete | Function | Set range | Default |
E1 | Lower setpoint limit | -40oC to Set temp. | -30oC |
E2 | Higher setpoint limit | Set temp.40oC | 30oC |
E3 | Temp.hysteresis | 1 to 10oC | 4oC |
E4 | Comp.start delay time | 0 to 10Min | 2Min |
E5 | Offset on room temp. | -5 to 5oC | 0 |
F1 | Max.Defrost duration | 1 to 60Min | 20Min |
F2 | Defrost interval time | 0 to 24Hr | 6Hr |
F4 | Display during defrost | 0=Normal display 1=Last value before defrost |
0 |
C2 | High temperature alarm | 0 to 40oC above setpoint | 20 |
C3 | Low temperature alarm | Below setpoint -40oC to 0 | -20 |
C4 | Alarm delay time | 1 to 90Min | 60Min |