Description
Features
Automatic refrigerating&heating switch
accurately 0.1℃ control
Temperature Control
Highest and Lowest Temperature Record
Value Storing / Self Testing
Technical Data
Range of temperature display:-45~125℃ (-49~240℉)
Accuracy:±1℃/2℉
Temperature of the operating environment:-10~60℃(14~140℉)
Relative Humidity:20%~90%(Non-condensing)
Compressor: N.O. 20A/250VAC
Heater: N.O. 10A/250VAC
Fan : N.O. 8A/250VAC
Dimension:77(Length)×35(Width)×60(Depth)mm
Mounting hole dimension:71(Length)×29(Width)mm
Parameters
Paramete
|
Function
|
Set range
|
Default
|
E1
|
Comp. start delay time
|
0~10Min
|
2Min
|
E2
|
Offset on room temp.
|
-20.0~20.0℃
-36.0~36.0℉ |
0
|
F1
|
Refrigeration start temp.
|
17.0~19.9℃
62.6~67.8℉ |
17.7℃
63.8℉ |
F2
|
Refrigeration start temp.
|
17.0~19.9℃
62.6~67.8℉ |
17.0℃
62.6℉ |
F3
|
Heating start temp.
|
15.0~17.0℃
59.0~62.6℉ |
16.3℃
61.3℉ |
F4
|
Heating start temp.
|
15.0~17.0℃
59.0~62.6℉ |
17.0℃
62.6℉ |
C1
|
Temperature unit
|
0=Celsius 1=Fahrenheit
|
0
|
C2
|
High temperature alarm
|
0~99℃
32~210.2℉ |
20℃
68℉ |
C3
|
Lowe temperature alarm
|
-40~99℃
-40~210.2℉ |
15℃
59℉ |
C4
|
Time delay of alarm when working
|
0~90Min
|
60Min
|
C5
|
Operation modes switch delay time
|
0~30Min
|
10Min
|