50W 12V/24V/5V/15V Single Output switching power supply

(No reviews yet) Write a Review
SKU:
PPBQ-UC7I-Q2CL
Weight:
0.20 KGS
US $10.70

Description

 

   Model

 

Specification

50-5

50-12

50-15

50-24

DC Output voltage

5V

12V

15V

24V

Output voltage range(Note:2)

±2%

±1%

±1%

±1%

Rated output current

10A

4.2A

3.4A

2.1A

Output current range

0~10A

0~4.2A

0~3.4A

0~2.1A

Wave and noise(Note:3)

75mVp-p

60mVp-p

60mVp-p

50mVp-p

Inlet stability(Note:4)

±0.5%

±0.5%

±0.5%

±0.5%

Load stability(Note:5)

±1%

±0.5%

±0.5%

±0.5%

DC output power

50W

50.4W

51W

50.4W

Efficiency

71%

78%

78%

80%

Adjustable range for DC voltage

+10,-5%

±10%

±10%

±10%

AC input voltage range

85~132VAC/170~264VAC selected by switch 47~63Hz,240~370VDC

Input current

1.3A/115V  0.65A/230V

AC Inrush current

Cold-start current 18A/115V  36A/230V

Leakage current

<0.5mA/240VAC

Overload protection

105%-150% Type: pulsing hiccup shutdown  Reset: auto recovery

Over-voltage protection

115%~135% Protection type :shut off output

Temperature coefficient

±0.03%(0~50degree Celsius)

Setup, rise, hold up time

200ms, 100ms, 30ms

Vibration

10~500Hz, 2G 10min,/1 cycle. Period for 60min,Each axes

Withstand voltage

I/P-O/P:1.5KVAC  I/P-FG:1.5KVAC  O/P-FG:0.5KVAC

Isolation resistance

I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC

Working temperature and humidity

-10~+60degree Celsius(Refer to output load derating curve),20%~90%RH

Store temperature and humidity

-20~+85degree Celsius,10%~95%RH

Overall dimension

85X58X34mm (L*W*H)

Weight

0.44kgS

Safety standards

Meet UL 1012 requirement(Not apply for the mark)

EMC standards

....................................

Note

1. The parameter under the testing condition : 230vAC input ,rated load,25degree Celsius70% RH. Temperature.

2. Tolerance the setting tolerance, circuit stability and load stability.(Note:5).

3. Wave test: adopting "A12"double wire for 20MHz, and 0.1 UF&47UF capacitor short-circuit for interrupting.

4. Inlet voltage stability test : the lowest voltage will be up to the highest voltage when the circuit overload.

5. Load stability test: The load is from 0% to 100%.

View AllClose